tag or keyword Search the whole station

KRY -20℃~100℃
KRY -20℃~100℃
KRY -20℃~100℃

KRY -20℃~100℃ Low temperature chiller

Control 6 test equipment at the same time, with consistent temperature and independent pressure/flow control
  • Heating Power15kW~38kW
  • Cooling capacity10kW~60kW
  • Power range36kW~75kW
  • Temperature accuracy±0.5℃
  • Flow accuracy/platform±0.2L
  • RefrigerantR404A/R507C
  • Weight900KG~1750KG
  • Details

Parameters Description

Temperature range is -20℃~+100℃, which can be extended to +135℃ according to the actual situation, and the temperature control accuracy is plus or minus 0.5℃. The equipment can control the flow and pressure independently while controlling the temperature, and different customized solutions are required for simultaneous control.


The tested object is attached to a test platform adapter.
The inside of the part was cooled and heated by an aqueous solution of ethylene glycol.
The test component needs to go through a specific temperature profile and record changes in temperature.
When performing a tolerance test, it usually takes an infinite loop.

Equipped with a powerful circulation pump while ensuring the delivery of highly viscous liquids.
Control the flow output with variable frequency regulation or proportional control valve to achieve high precision control total range 5%~100% adjustment.

ModelKRY-2A25W/6SKRY-2A38W/6SKRY-2A60W/6S
Temp Range-20℃~+100℃
Temperature control precision±0.5℃±0.5℃±0.5℃
Temperature feedbackPt100Pt100Pt100
Temperature display0.01k0.01k0.01k
Flow control/Group1~20 L/min1~20 L/min1~40 L/min
Flow control accuracy/Group±0.2L±0.2L±0.2L
Number of fluid output groups6 groups6 groups6 groups
Flow descriptionWhen the temperature control is lower than -30℃, the flow rate is controlled within 80% of the maximum value.
Flow pressure descriptionThe unit can control the flow individually or separately. Need to control different solutions at the same time (customized)
Heating Power15KW25KW38KW
cooling capacity100℃25KW38KW60KW
20℃25KW38KW60KW
0℃25KW38KW60KW
-20℃10KW15KW24KW
CompressionEmerson Valley Wheel Compressor
Expansion valve/solenoid valveDanfoss Thermal Expansion Valve / Emerson Solenoid Valve
Oil distributorEmerson
Dry filter, Pressure controlDanfoss
EvaporatorPlate heat exchanger
Circulating pumpMagnetic drive pump
Frequency converterDelta
Flow,Pressure sensorElectromagnetic flowmeter, Johnson Controls pressure sensor
Input, Display5 inch color touch screen \ PLC controller
CommunicationModbus RTU protocol RS485 interface, optional CAN communication bus, Ethernet interface TCP/IP protocol
Safety protectionWith self-diagnosis function; Refrigerator overload protection; High pressure switch, overload relay, thermal protection
systemabsorb water in the air, the system in operation will not because of high temperature pressure rise, low temperature
 automatically add heat conduction medium.
refrigerantR404A/R507C
Connection sizeThere are six groups of inlet and outlet,ZG3/4
Cooling water@20C8000L/H12000L/H20000L/H
Condenser(W)Shenshi tube type heat exchanger
Condenser(A)Optional air-cooled type, upper air outlet, the equipment size will be increased.
Power 380V50HZ36KW max51KW max75KW max
Dimension cm200*145*205200*145*205200*145*205
Weight(W)900kg1100kg1750kg
Optional220V 60HZ Three phase  400V 50HZ Three phase  440V 60HZ Three phase
OptionalExtend to -40~+135℃
OptionalThe size external circulation pipe line is DN15 or DN20, do not throttle, which will increase the circulation pump load,
 pipe need to be insulated, and adopt rubber and plastic insulation pipe which can afford high temp.

Configuration Details

Working Principle

Temperature simulation for vehicle quality test: battery life test, fuel injector/motor test bench, airbag test, component test bench, etc. It can simulate the external environmental conditions in the climate chamber or replace the internal system, which can create the necessary actual temperature conditions for the test bench.

Test temperature of main test items of vehicle electronics:
IC test conditions for locomotives: -40℃~125℃, wind blowing, sun exposure, high vibration;
Instrument panel operation test test conditions: -40℃~85℃;
Motor controller test conditions: operating test temperature: 40 ℃ ~ 110 ℃;
Satellite positioning (GPS) Test conditions: high temperature operation test temperature: 85℃; low temperature operation test temperature: -40℃;
Compound vibration: -40℃~80℃;
Obviously the best solution is for the test house to have temperature simulation system equipment.

The model KRY -20℃~100℃ products can water-cooled and air-cooled.