tag or keyword Search the whole station

KRY 0℃~100℃
KRY 0℃~100℃
KRY 0℃~100℃
KRY 0℃~100℃
KRY 0℃~100℃
KRY 0℃~100℃

KRY 0℃~100℃ Normal temperature chiller

Vehicle antifreeze test temperature simulation
  • Heating Power2.5kW~38kW
  • Cooling capacity2.5kW~60kW
  • Power range4.5kW~82kW
  • Temperature accuracy±0.5℃
  • Flow rate output2~50 L/min
  • RefrigerantR404A/R507C/R125/N40
  • Weight250KG~2400KG
  • Details

Parameters Description

  

Temperature range is 0℃~+100℃, which can be extended to +135℃ according to the actual situation, and the temperature control accuracy is plus or minus 0.5℃. The  equipment can control the flow and pressure independently while controlling the temperature, and different customized solutions are required for simultaneous control.


   The tested object is attached to a test platform adapter.
   The inside of the part was cooled and heated by an aqueous solution of ethylene glycol.
  The test component needs to go through a specific temperature profile and record changes in temperature.
   When performing a tolerance test, it usually takes an infinite loop.

   Equipped with a powerful circulation pump while ensuring the delivery of highly viscous liquids.
  Control the flow output with variable frequency regulation or proportional control valve to achieve high precision control total range 5%~100% adjustment.

KRY 0℃~100℃

ModelKRY-25KRY-55KRY-75KRY-A10KRY-A15KRY-A25KRY-A38WKRY-A60W
KRY-A15WKRY-A25W
Temp. Range0℃~+100℃
Temp. control precision±0.5℃±0.5℃±0.5℃±0.5℃±0.5℃±0.5℃±0.5℃±0.5℃
Temp. feedbackPt100Pt100Pt100Pt100Pt100Pt100Pt100Pt100
Temp. display0.01k0.01k0.01k0.01k0.01k0.01k0.01k0.01k
Flow rate output2~20 L/min2~25 L/min2~25 L/min2~25 L/min2~25 L/min2~25 L/min5~50 L/min5~50 L/min
Flow rate accuracy±0.2 L/min±0.2 L/min±0.2 L/min±0.2 L/min±0.2 L/min±0.2 L/min±0.2 L/min±0.2 L/min
Pressure displayAdopt the Jeffron pressure sensor, the touch screen display the pressure, can carry on the pressure control adjustment.
Heating power2.5kW5.5kW7.5kW10kW10kW15kW25kW38kW
 Optional 15kWOptional 25kWOptional 38kWOptional 60kW
cooling capacity100℃2.5kW5.5kW7.5kW10kW15kW25kW38kW60kW
 20℃2.5kW5.5kW7.5kW10kW15kW25kW38kW60kW
 5℃1.8kW3.8kW5.2kW7kW11kW18kW27kW42kW
compressionHITACHIEmerson Valley Wheel Compressor
expansionDanfoss  Thermal Expansion Valve/ Emerson Solenoid
oil distributorEmerson
Dry filter, PressureEmerson/Danfoss
EvaporatorPlate heat exchanger
input, Display7 inch color touch screen \ PLC controller
program edit5 programs can be prepared, each program can be prepared 20 steps
CommunicationCAN communications bus
Safety protectionWith self-diagnosis function; Refrigerator overload protection; High pressure switch, overload relay, thermal protection
device, low liquid level protection, high temperature protection, sensor fault protection and other safety functions
is it a fully closed systemThe whole system is a fully closed system, there will be no oil mist at high temperature, and the water in the air will not be absorbed at low temperature. The system will not increase the pressure due to high temperature in operation, and the thermal conduction medium will be automatically supplemented at low temperature.
refrigerantR404A/ R507C  export adopt R448A
Flow sensorGerman brand flowmeter
Connection sizeZG3/4ZG3/4ZG3/4ZG3/4ZG3/4ZG3/4ZG3/4ZG3/4
Cooling water at 20C°    3200L/H6000L/H9000L/H15000L/H
Condenser(W)Tube type heat exchanger (Paris/Shenshi)
Condenser(A)Copper tube aluminum finned heat exchanger (upward wind)
Power 380V50HZ4.5kW220V8.5kW11.5kW16kW18kW28kW40kW61kW
Dimension cm40*70*16055*100*17555*100*17570*100*17580*120*185100*150*185100*150*185100*150*185
Weight 250kg280kg320kg360kg620kg890kg1300KG
Optional220V 60HZ three phase    460V 60HZ three phase
OptionalHigher precision control of temperature, flow and pressure
OptionalAutomatic antifreeze filling system
OptionalAutomatic liquid recovery system

KRY 0℃~100℃ 1&2s (2 sets of auxiliary temperature control, pressure/flow controlled separately)

ModelKRY-75/2SKRY-A15/2SKRY-A25W/2SKRY-A38W/2SKRY-A60W/2S
KRY-75W/2SKRY-A15W/2S
Temp. Range0℃~+100℃
Temp. control precision±0.5℃±0.5℃±0.5℃±0.5℃±0.5℃
Temp. feedbackPt100Pt100Pt100Pt100Pt100
Temp. display0.01k0.01k0.01k0.01k0.01k
Flow control/Group2~25 L/min2~25 L/min2~25L/min5~50 L/min5~50 L/min
Flow control accuracy/Group±0.2L±0.2L±0.2L±0.2L±0.2L
Number of fluid output groups2 Groups2 Groups2 Groups2 Groups2 Groups
pressure control/Group0.2bar~2.5bar0.2bar~2.5bar0.2bar~2.5bar0.2bar~2.5bar0.2bar~2.5bar
flow pressure descriptionThe equipment can control flow and pressure separately. need to control at the same time using different solutions (to be customized)
Heating power10kW10kW15kW25kW38kW
cooling capacity100℃10kW15kW25kW38kW60kW
20℃10kW15kW25kW38kW60kW
5℃7kW11kW18kW27kW42kW
compressionEmerson Valley Wheel Compressor
expansionDanfoss  Thermal Expansion Valve/ Emerson Solenoid
oil distributorEmerson
Dry filter, PressureEmerson/Danfoss
EvaporatorPlate heat exchanger
Ciriulating pumpMagnetic pump
FrequencyDelta
Flow, Pressure sensorGerman brand flowmeter, johnson Controls pressure
input, Display5 inch color touch screen \ Siemens S7-1200 PLC controller
CommunicationModbus RTU protocol RS485 interface, optional CAN communication bus, Ethernet interface TCP/IP protocol
Safety protectionWith self-diagnosis function; Refrigerator overload protection; High pressure switch, overload relay, thermal protection
device, low liquid level protection, high temperature protection, sensor fault protection and other safety functions
refrigerantR404A/R507C/R125/N40 All four refrigerants are available
Connection sizeThere are two groups of inlet and outlet,G3/4
Cooling water at 20C°2600L/H3200L/H6000L/H9000L/H15000L/H
Condenser(W)Shenshi tube type heat exchanger
Power 380V50HZ17kW20kW31kW43kW65kW
Dimension cm70*100*17580*120*185100*150*185120*180*205145*205*225
Weight360KG450kg750kg1000kg1700kg
Optional220V 60HZ three phase    460V 60H three phase

KRY 0℃~100℃ 1&2T (Temperature/pressure/flow can be independently controlled)

ModelKRY-25/2TKRY-55/2TKRY-75/2TKRY-A10/2TKRY-A15/2TKRY-A25/2TKRY-A38W/2TKRY-A60W/2T
Temp. Range0℃~+100℃
Temp. control precision±0.5℃
Temp. feedbackPt100
Temp. display0.01k
Flow rate output2~20 L/min2~25 L/min2~25 L/min2~25 L/min2~25 L/min2~25 L/min5~50 L/min5~50 L/min
Flow rate accuracy±0.2 L/min±0.2 L/min±0.2 L/min±0.2 L/min±0.2 L/min±0.2 L/min±0.2 L/min±0.2 L/min
Pressure displayAdopt the Jeffron pressure sensor, the touch screen display the pressure, can carry on the pressure control adjustment.
Heating power2.5kW*25.5kW*27.5kW*210kW*210kW*215kW*225kW*238kW*2
Optional 15kWOptional 25kWOptional 38kWOptional 60kW
cooling capacity100℃2.5kW*25.5kW*27.5kW*210kW*215kW*225kW*238kW*260kW*2
20℃2.5kW*25.5kW*27.5kW*210kW*215kW*225kW*238kW*260kW*2
5℃1.8kW*23.8kW*25.2kW*27kW*211kW*218kW*227kW*242kW*2
compressionHITACHIEmerson Valley Wheel Compressor
expansionDanfoss Thermal Expansion Valve/ Emerson Solenoid
oil distributorEmerson
Dry filter, PressureEmerson/Danfoss
Evaporatorplate heat exchanger
input, Display7 inch color touch screen \ PLC controller
program edit5 programs can be prepared, each program can be prepared 40 steps
CommunicationCAN communications bus
Safety protectionWith self-diagnosis function; Refrigerator overload protection; High pressure switch, overload relay, thermal protection
device, low liquid level protection, high temperature protection, sensor fault protection and other safety functions
is it a fully closed systemThe whole system is a fully closed system, there will be no oil mist at high temperature, and the water in the air will not be absorbed at low temperature. The system will not increase the pressure due to high temperature in operation, and the thermal conduction medium will be automatically supplemented at low temperature.
refrigerantR404A/ R507C export adopt R448A
Flow sensorGerman brand flowmeter
Connection sizeZG3/4ZG3/4ZG3/4ZG3/4ZG3/4ZG3/4ZG3/4ZG3/4
Cooling water at 20C°    5600L/H10000L/H17000L/H24000L/H
G1 1/8DN40DN50DN65
Condenser(W)Tube type heat exchanger (Paris/Shenshi)
Condenser(A)Copper tube aluminum finned heat exchanger (upward wind)
Power 380V50HZ9kW220V19kW23kW29kW34kW52kW80kW120kW
Dimension (A)cm55*100*17570*100*17580*120*185100*150*185100*150*185145*205*205145*205*225145*245*225
Weight260KG320KG400KG580KG750KG1250KG1600KG2400KG
Optional220V 60HZ three phase 460V 60HZ three phase
OptionalHigher precision control of temperature, flow and pressure
OptionalAutomatic antifreeze filling system,Automatic liquid recovery system
OptionalLiquid low level protection

KRY 0℃~100℃ 1&3S (3 sets of auxiliary temperature control, pressure/flow controlled separately)

ModelKRY-A15W/3SKRY-A25W/3SKRY-A38W/3SKRY-A60W/3S
KRY-A15/3SKRY-A25/3S
Temp. Range0℃~+100℃
Temp. control precision±0.5℃±0.5℃±0.5℃±0.5℃
Temp. feedbackPt100Pt100Pt100Pt100
Temp. display0.01k0.01k0.01k0.01k
Flow control/Group2~25 L/min2~25 L/min2~25 L/min1~25 L/min
Flow control accuracy/Group±0.2L±0.2L±0.2L±0.2L
Number of fluid output groups3 Groups3 Groups3 Groups3 Groups
pressure control/Group0.2bar~2.5bar0.2bar~2.5bar0.2bar~2.5bar0.2bar~2.5bar
flow pressure descriptionThe equipment can control flow and pressure separately. need to control at the same time using different solutions (to be customized)
Heating power10kW15kW25kW38kW
cooling capacity100℃15kW25kW38kW60kW
20℃15kW25kW38kW60kW
5℃11kW18kW27kW42kW
compressionEmerson Valley Wheel Compressor
expansionDanfoss  Thermal Expansion Valve/ Emerson Solenoid
oil distributorEmerson
Dry filter, PressureDanfoss
EvaporatorPlate heat exchanger
Ciriulating pumpNangfang centrifugal pump can be selected with imported brand magnetic pump
FrequencyDelta
Flow, Pressure sensorGerman brand flowmeter, johnson Controls pressure
input, Display7-inch color touch screen \ PLC controller
CommunicationModbus RTU protocol RS485 interface, optional CAN communication bus, Ethernet interface TCP/IP protocol
Safety protectionWith self-diagnosis function; Refrigerator overload protection; High pressure switch, overload relay, thermal protection
device, low liquid level protection, high temperature protection, sensor fault protection and other safety functions
refrigerantR404A/R507C/R125/N40 All four refrigerants are available
Connection sizeThere are three groups of inlet and outlet,ZG3/4
Cooling water at 20C°3200L/H6000L/H9000L/H15000L/H
Condenser(W)Shenshi tube type heat exchanger
Power 380V50HZ22kW33kW45kW68kW
Dimension cm80*120*185100*150*185100*150*185100*150*185
Weight420kg750kg1000kg1700kg
Optional220V 60HZ three phase    460V 60H three phase
OptionalThe size external circulation pipe line is DN15 or DN20, do not throttle, which will increase the circulation pump load,
pipe need to be insulated, and adopt rubber and plastic insulation pipe which can afford high temp.
OptionalWhen the temperature is lower than the normal temperature, the refrigeration system adopts the refrigeration PID to adjust the cooling capacity, and does not adopt the heating countermeasures, so as to achieve the purpose of energy saving

KRY 0℃~100℃ 1&6S (6 sets of auxiliary temperature control, pressure and flow controlled separately)

ModelKRY-A25W/6SKRY-A38W/6SKRY-A60W/6S
Temp. Range0℃~+100℃
Temp. control precision±0.5℃±0.5℃±0.5℃
Temp. feedbackPt100Pt100Pt100
Temp. display0.01k0.01k0.01k
Flow control/Group2~20 L/min2~20 L/min2~20 L/min
Flow control accuracy/Group±0.2L±0.2L±0.2L
Number of fluid output groups6 Groups6 Groups6 Groups
pressure control/Group0.2bar~2.5bar0.2bar~2.5bar0.2bar~2.5bar
flow pressure descriptionThe equipment can control flow and pressure separately. need to control at the same time using different solutions (to be customized)
Heating power15kW25kW38kW
cooling capacity100℃25kW38kW60kW
20℃25kW38kW60kW
5℃18kW27kW42kW
compressionEmerson Valley Wheel Compressor
expansionElectronic Expansion Valve
oil distributorEmerson
Dry filter, PressureDanfoss
EvaporatorPlate heat exchanger
Ciriulating pumpNangfang centrifugal pump can be selected with imported brand magnetic pump
FrequencyDelta
Flow, Pressure sensorGerman brand flowmeter, johnson Controls pressure
input, Display5 inch color touch screen \ PLC controller
CommunicationModbus RTU protocol RS485 interface, optional CAN communication bus, Ethernet interface TCP/IP protocol
Safety protectionWith self-diagnosis function; Refrigerator overload protection; High pressure switch, overload relay, thermal protection
device, low liquid level protection, high temperature protection, sensor fault protection and other safety functions
is it a fully closed systemThe whole system is a fully closed system, there will be no oil mist at high temperature, and the water in the air will not be absorbed at low temperature. The system will not increase the pressure due to high temperature in operation, and the thermal conduction medium will be automatically supplemented at low temperature.
refrigerantR404A/R507C/R125/N40  All four refrigerants are available
Connection sizeThere are six groups of inlet and outlet,ZG3/4
Cooling water at 20C°6000L/H9000L/H15000L/H
Condenser(W)Shenshi tube type heat exchanger
Power 380V50HZ38kW55kW82kW
Dimension cm200*145*205200*145*205200*145*205
Weight900kg1200kg1950kg
Optional220V 60HZ three phase    460V 60H three phase
OptionalExtend to -40~+135℃
OptionalThe size external circulation pipe line is DN15 or DN20, do not throttle, which will increase the circulation pump load,
pipe need to be insulated, and adopt rubber and plastic insulation pipe which can afford high temp.
OptionalWhen the temperature is lower than the normal temperature, the refrigeration system adopts the refrigeration PID to adjust the cooling capacity, and does not adopt the heating countermeasures, so as to achieve the purpose of energy saving

Configuration Details

Working Principle

Temperature simulation for vehicle quality test: battery life test, fuel injector/motor test bench, airbag test, component test bench, etc. It can simulate the external environmental conditions in the climate chamber or replace the internal system, which can create the necessary actual temperature conditions for the test bench.

  

Test temperature of main test items of vehicle electronics:


   IC test conditions for locomotives: -40℃~125℃, wind blowing, sun exposure, high vibration;
   Instrument panel operation test test conditions: -40℃~85℃;
  Motor controller test conditions: operating test temperature: 40 ℃ ~ 110 ℃;
Satellite positioning (GPS) Test conditions: high temperature operation test temperature: 85℃; low temperature operation test temperature: -40℃;
  Compound vibration: -40℃~80℃;
  Obviously the best solution is for the test house to have temperature simulation system equipment.

The model KRY 0℃~100℃ products can water-cooled chiller and air-cooled chiller.