KRY 0℃~100℃ Normal temperature chiller
Vehicle antifreeze test temperature simulation- Heating Power2.5kW~38kW
- Cooling capacity2.5kW~60kW
- Power range4.5kW~82kW
- Temperature accuracy±0.5℃
- Flow rate output2~50 L/min
- RefrigerantR404A/R507C/R125/N40
- Weight250KG~2400KG
- Details
Parameters Description
Temperature range is 0℃~+100℃, which can be extended to +135℃ according to the actual situation, and the temperature control accuracy is plus or minus 0.5℃. The equipment can control the flow and pressure independently while controlling the temperature, and different customized solutions are required for simultaneous control.
The tested object is attached to a test platform adapter.
The inside of the part was cooled and heated by an aqueous solution of ethylene glycol.
The test component needs to go through a specific temperature profile and record changes in temperature.
When performing a tolerance test, it usually takes an infinite loop.
Equipped with a powerful circulation pump while ensuring the delivery of highly viscous liquids.
Control the flow output with variable frequency regulation or proportional control valve to achieve high precision control total range 5%~100% adjustment.
KRY 0℃~100℃
Model | KRY-25 | KRY-55 | KRY-75 | KRY-A10 | KRY-A15 | KRY-A25 | KRY-A38W | KRY-A60W | |
KRY-A15W | KRY-A25W | ||||||||
Temp. Range | 0℃~+100℃ | ||||||||
Temp. control precision | ±0.5℃ | ±0.5℃ | ±0.5℃ | ±0.5℃ | ±0.5℃ | ±0.5℃ | ±0.5℃ | ±0.5℃ | |
Temp. feedback | Pt100 | Pt100 | Pt100 | Pt100 | Pt100 | Pt100 | Pt100 | Pt100 | |
Temp. display | 0.01k | 0.01k | 0.01k | 0.01k | 0.01k | 0.01k | 0.01k | 0.01k | |
Flow rate output | 2~20 L/min | 2~25 L/min | 2~25 L/min | 2~25 L/min | 2~25 L/min | 2~25 L/min | 5~50 L/min | 5~50 L/min | |
Flow rate accuracy | ±0.2 L/min | ±0.2 L/min | ±0.2 L/min | ±0.2 L/min | ±0.2 L/min | ±0.2 L/min | ±0.2 L/min | ±0.2 L/min | |
Pressure display | Adopt the Jeffron pressure sensor, the touch screen display the pressure, can carry on the pressure control adjustment. | ||||||||
Heating power | 2.5kW | 5.5kW | 7.5kW | 10kW | 10kW | 15kW | 25kW | 38kW | |
Optional 15kW | Optional 25kW | Optional 38kW | Optional 60kW | ||||||
cooling capacity | 100℃ | 2.5kW | 5.5kW | 7.5kW | 10kW | 15kW | 25kW | 38kW | 60kW |
20℃ | 2.5kW | 5.5kW | 7.5kW | 10kW | 15kW | 25kW | 38kW | 60kW | |
5℃ | 1.8kW | 3.8kW | 5.2kW | 7kW | 11kW | 18kW | 27kW | 42kW | |
compression | HITACHI | Emerson Valley Wheel Compressor | |||||||
expansion | Danfoss Thermal Expansion Valve/ Emerson Solenoid | ||||||||
oil distributor | Emerson | ||||||||
Dry filter, Pressure | Emerson/Danfoss | ||||||||
Evaporator | Plate heat exchanger | ||||||||
input, Display | 7 inch color touch screen \ PLC controller | ||||||||
program edit | 5 programs can be prepared, each program can be prepared 20 steps | ||||||||
Communication | CAN communications bus | ||||||||
Safety protection | With self-diagnosis function; Refrigerator overload protection; High pressure switch, overload relay, thermal protection | ||||||||
device, low liquid level protection, high temperature protection, sensor fault protection and other safety functions | |||||||||
is it a fully closed system | The whole system is a fully closed system, there will be no oil mist at high temperature, and the water in the air will not be absorbed at low temperature. The system will not increase the pressure due to high temperature in operation, and the thermal conduction medium will be automatically supplemented at low temperature. | ||||||||
refrigerant | R404A/ R507C export adopt R448A | ||||||||
Flow sensor | German brand flowmeter | ||||||||
Connection size | ZG3/4 | ZG3/4 | ZG3/4 | ZG3/4 | ZG3/4 | ZG3/4 | ZG3/4 | ZG3/4 | |
Cooling water at 20C° | 3200L/H | 6000L/H | 9000L/H | 15000L/H | |||||
Condenser(W) | Tube type heat exchanger (Paris/Shenshi) | ||||||||
Condenser(A) | Copper tube aluminum finned heat exchanger (upward wind) | ||||||||
Power 380V50HZ | 4.5kW220V | 8.5kW | 11.5kW | 16kW | 18kW | 28kW | 40kW | 61kW | |
Dimension cm | 40*70*160 | 55*100*175 | 55*100*175 | 70*100*175 | 80*120*185 | 100*150*185 | 100*150*185 | 100*150*185 | |
Weight | 250kg | 280kg | 320kg | 360kg | 620kg | 890kg | 1300KG | ||
Optional | 220V 60HZ three phase 460V 60HZ three phase | ||||||||
Optional | Higher precision control of temperature, flow and pressure | ||||||||
Optional | Automatic antifreeze filling system | ||||||||
Optional | Automatic liquid recovery system |
KRY 0℃~100℃ 1&2s (2 sets of auxiliary temperature control, pressure/flow controlled separately)
Model | KRY-75/2S | KRY-A15/2S | KRY-A25W/2S | KRY-A38W/2S | KRY-A60W/2S | |
KRY-75W/2S | KRY-A15W/2S | |||||
Temp. Range | 0℃~+100℃ | |||||
Temp. control precision | ±0.5℃ | ±0.5℃ | ±0.5℃ | ±0.5℃ | ±0.5℃ | |
Temp. feedback | Pt100 | Pt100 | Pt100 | Pt100 | Pt100 | |
Temp. display | 0.01k | 0.01k | 0.01k | 0.01k | 0.01k | |
Flow control/Group | 2~25 L/min | 2~25 L/min | 2~25L/min | 5~50 L/min | 5~50 L/min | |
Flow control accuracy/Group | ±0.2L | ±0.2L | ±0.2L | ±0.2L | ±0.2L | |
Number of fluid output groups | 2 Groups | 2 Groups | 2 Groups | 2 Groups | 2 Groups | |
pressure control/Group | 0.2bar~2.5bar | 0.2bar~2.5bar | 0.2bar~2.5bar | 0.2bar~2.5bar | 0.2bar~2.5bar | |
flow pressure description | The equipment can control flow and pressure separately. need to control at the same time using different solutions (to be customized) | |||||
Heating power | 10kW | 10kW | 15kW | 25kW | 38kW | |
cooling capacity | 100℃ | 10kW | 15kW | 25kW | 38kW | 60kW |
20℃ | 10kW | 15kW | 25kW | 38kW | 60kW | |
5℃ | 7kW | 11kW | 18kW | 27kW | 42kW | |
compression | Emerson Valley Wheel Compressor | |||||
expansion | Danfoss Thermal Expansion Valve/ Emerson Solenoid | |||||
oil distributor | Emerson | |||||
Dry filter, Pressure | Emerson/Danfoss | |||||
Evaporator | Plate heat exchanger | |||||
Ciriulating pump | Magnetic pump | |||||
Frequency | Delta | |||||
Flow, Pressure sensor | German brand flowmeter, johnson Controls pressure | |||||
input, Display | 5 inch color touch screen \ Siemens S7-1200 PLC controller | |||||
Communication | Modbus RTU protocol RS485 interface, optional CAN communication bus, Ethernet interface TCP/IP protocol | |||||
Safety protection | With self-diagnosis function; Refrigerator overload protection; High pressure switch, overload relay, thermal protection | |||||
device, low liquid level protection, high temperature protection, sensor fault protection and other safety functions | ||||||
refrigerant | R404A/R507C/R125/N40 All four refrigerants are available | |||||
Connection size | There are two groups of inlet and outlet,G3/4 | |||||
Cooling water at 20C° | 2600L/H | 3200L/H | 6000L/H | 9000L/H | 15000L/H | |
Condenser(W) | Shenshi tube type heat exchanger | |||||
Power 380V50HZ | 17kW | 20kW | 31kW | 43kW | 65kW | |
Dimension cm | 70*100*175 | 80*120*185 | 100*150*185 | 120*180*205 | 145*205*225 | |
Weight | 360KG | 450kg | 750kg | 1000kg | 1700kg | |
Optional | 220V 60HZ three phase 460V 60H three phase |
KRY 0℃~100℃ 1&2T (Temperature/pressure/flow can be independently controlled)
Model | KRY-25/2T | KRY-55/2T | KRY-75/2T | KRY-A10/2T | KRY-A15/2T | KRY-A25/2T | KRY-A38W/2T | KRY-A60W/2T | |
Temp. Range | 0℃~+100℃ | ||||||||
Temp. control precision | ±0.5℃ | ||||||||
Temp. feedback | Pt100 | ||||||||
Temp. display | 0.01k | ||||||||
Flow rate output | 2~20 L/min | 2~25 L/min | 2~25 L/min | 2~25 L/min | 2~25 L/min | 2~25 L/min | 5~50 L/min | 5~50 L/min | |
Flow rate accuracy | ±0.2 L/min | ±0.2 L/min | ±0.2 L/min | ±0.2 L/min | ±0.2 L/min | ±0.2 L/min | ±0.2 L/min | ±0.2 L/min | |
Pressure display | Adopt the Jeffron pressure sensor, the touch screen display the pressure, can carry on the pressure control adjustment. | ||||||||
Heating power | 2.5kW*2 | 5.5kW*2 | 7.5kW*2 | 10kW*2 | 10kW*2 | 15kW*2 | 25kW*2 | 38kW*2 | |
Optional 15kW | Optional 25kW | Optional 38kW | Optional 60kW | ||||||
cooling capacity | 100℃ | 2.5kW*2 | 5.5kW*2 | 7.5kW*2 | 10kW*2 | 15kW*2 | 25kW*2 | 38kW*2 | 60kW*2 |
20℃ | 2.5kW*2 | 5.5kW*2 | 7.5kW*2 | 10kW*2 | 15kW*2 | 25kW*2 | 38kW*2 | 60kW*2 | |
5℃ | 1.8kW*2 | 3.8kW*2 | 5.2kW*2 | 7kW*2 | 11kW*2 | 18kW*2 | 27kW*2 | 42kW*2 | |
compression | HITACHI | Emerson Valley Wheel Compressor | |||||||
expansion | Danfoss Thermal Expansion Valve/ Emerson Solenoid | ||||||||
oil distributor | Emerson | ||||||||
Dry filter, Pressure | Emerson/Danfoss | ||||||||
Evaporator | plate heat exchanger | ||||||||
input, Display | 7 inch color touch screen \ PLC controller | ||||||||
program edit | 5 programs can be prepared, each program can be prepared 40 steps | ||||||||
Communication | CAN communications bus | ||||||||
Safety protection | With self-diagnosis function; Refrigerator overload protection; High pressure switch, overload relay, thermal protection | ||||||||
device, low liquid level protection, high temperature protection, sensor fault protection and other safety functions | |||||||||
is it a fully closed system | The whole system is a fully closed system, there will be no oil mist at high temperature, and the water in the air will not be absorbed at low temperature. The system will not increase the pressure due to high temperature in operation, and the thermal conduction medium will be automatically supplemented at low temperature. | ||||||||
refrigerant | R404A/ R507C export adopt R448A | ||||||||
Flow sensor | German brand flowmeter | ||||||||
Connection size | ZG3/4 | ZG3/4 | ZG3/4 | ZG3/4 | ZG3/4 | ZG3/4 | ZG3/4 | ZG3/4 | |
Cooling water at 20C° | 5600L/H | 10000L/H | 17000L/H | 24000L/H | |||||
G1 1/8 | DN40 | DN50 | DN65 | ||||||
Condenser(W) | Tube type heat exchanger (Paris/Shenshi) | ||||||||
Condenser(A) | Copper tube aluminum finned heat exchanger (upward wind) | ||||||||
Power 380V50HZ | 9kW220V | 19kW | 23kW | 29kW | 34kW | 52kW | 80kW | 120kW | |
Dimension (A)cm | 55*100*175 | 70*100*175 | 80*120*185 | 100*150*185 | 100*150*185 | 145*205*205 | 145*205*225 | 145*245*225 | |
Weight | 260KG | 320KG | 400KG | 580KG | 750KG | 1250KG | 1600KG | 2400KG | |
Optional | 220V 60HZ three phase 460V 60HZ three phase | ||||||||
Optional | Higher precision control of temperature, flow and pressure | ||||||||
Optional | Automatic antifreeze filling system,Automatic liquid recovery system | ||||||||
Optional | Liquid low level protection |
KRY 0℃~100℃ 1&3S (3 sets of auxiliary temperature control, pressure/flow controlled separately)
Model | KRY-A15W/3S | KRY-A25W/3S | KRY-A38W/3S | KRY-A60W/3S | |
KRY-A15/3S | KRY-A25/3S | ||||
Temp. Range | 0℃~+100℃ | ||||
Temp. control precision | ±0.5℃ | ±0.5℃ | ±0.5℃ | ±0.5℃ | |
Temp. feedback | Pt100 | Pt100 | Pt100 | Pt100 | |
Temp. display | 0.01k | 0.01k | 0.01k | 0.01k | |
Flow control/Group | 2~25 L/min | 2~25 L/min | 2~25 L/min | 1~25 L/min | |
Flow control accuracy/Group | ±0.2L | ±0.2L | ±0.2L | ±0.2L | |
Number of fluid output groups | 3 Groups | 3 Groups | 3 Groups | 3 Groups | |
pressure control/Group | 0.2bar~2.5bar | 0.2bar~2.5bar | 0.2bar~2.5bar | 0.2bar~2.5bar | |
flow pressure description | The equipment can control flow and pressure separately. need to control at the same time using different solutions (to be customized) | ||||
Heating power | 10kW | 15kW | 25kW | 38kW | |
cooling capacity | 100℃ | 15kW | 25kW | 38kW | 60kW |
20℃ | 15kW | 25kW | 38kW | 60kW | |
5℃ | 11kW | 18kW | 27kW | 42kW | |
compression | Emerson Valley Wheel Compressor | ||||
expansion | Danfoss Thermal Expansion Valve/ Emerson Solenoid | ||||
oil distributor | Emerson | ||||
Dry filter, Pressure | Danfoss | ||||
Evaporator | Plate heat exchanger | ||||
Ciriulating pump | Nangfang centrifugal pump can be selected with imported brand magnetic pump | ||||
Frequency | Delta | ||||
Flow, Pressure sensor | German brand flowmeter, johnson Controls pressure | ||||
input, Display | 7-inch color touch screen \ PLC controller | ||||
Communication | Modbus RTU protocol RS485 interface, optional CAN communication bus, Ethernet interface TCP/IP protocol | ||||
Safety protection | With self-diagnosis function; Refrigerator overload protection; High pressure switch, overload relay, thermal protection | ||||
device, low liquid level protection, high temperature protection, sensor fault protection and other safety functions | |||||
refrigerant | R404A/R507C/R125/N40 All four refrigerants are available | ||||
Connection size | There are three groups of inlet and outlet,ZG3/4 | ||||
Cooling water at 20C° | 3200L/H | 6000L/H | 9000L/H | 15000L/H | |
Condenser(W) | Shenshi tube type heat exchanger | ||||
Power 380V50HZ | 22kW | 33kW | 45kW | 68kW | |
Dimension cm | 80*120*185 | 100*150*185 | 100*150*185 | 100*150*185 | |
Weight | 420kg | 750kg | 1000kg | 1700kg | |
Optional | 220V 60HZ three phase 460V 60H three phase | ||||
Optional | The size external circulation pipe line is DN15 or DN20, do not throttle, which will increase the circulation pump load, | ||||
pipe need to be insulated, and adopt rubber and plastic insulation pipe which can afford high temp. | |||||
Optional | When the temperature is lower than the normal temperature, the refrigeration system adopts the refrigeration PID to adjust the cooling capacity, and does not adopt the heating countermeasures, so as to achieve the purpose of energy saving |
KRY 0℃~100℃ 1&6S (6 sets of auxiliary temperature control, pressure and flow controlled separately)
Model | KRY-A25W/6S | KRY-A38W/6S | KRY-A60W/6S | |
Temp. Range | 0℃~+100℃ | |||
Temp. control precision | ±0.5℃ | ±0.5℃ | ±0.5℃ | |
Temp. feedback | Pt100 | Pt100 | Pt100 | |
Temp. display | 0.01k | 0.01k | 0.01k | |
Flow control/Group | 2~20 L/min | 2~20 L/min | 2~20 L/min | |
Flow control accuracy/Group | ±0.2L | ±0.2L | ±0.2L | |
Number of fluid output groups | 6 Groups | 6 Groups | 6 Groups | |
pressure control/Group | 0.2bar~2.5bar | 0.2bar~2.5bar | 0.2bar~2.5bar | |
flow pressure description | The equipment can control flow and pressure separately. need to control at the same time using different solutions (to be customized) | |||
Heating power | 15kW | 25kW | 38kW | |
cooling capacity | 100℃ | 25kW | 38kW | 60kW |
20℃ | 25kW | 38kW | 60kW | |
5℃ | 18kW | 27kW | 42kW | |
compression | Emerson Valley Wheel Compressor | |||
expansion | Electronic Expansion Valve | |||
oil distributor | Emerson | |||
Dry filter, Pressure | Danfoss | |||
Evaporator | Plate heat exchanger | |||
Ciriulating pump | Nangfang centrifugal pump can be selected with imported brand magnetic pump | |||
Frequency | Delta | |||
Flow, Pressure sensor | German brand flowmeter, johnson Controls pressure | |||
input, Display | 5 inch color touch screen \ PLC controller | |||
Communication | Modbus RTU protocol RS485 interface, optional CAN communication bus, Ethernet interface TCP/IP protocol | |||
Safety protection | With self-diagnosis function; Refrigerator overload protection; High pressure switch, overload relay, thermal protection | |||
device, low liquid level protection, high temperature protection, sensor fault protection and other safety functions | ||||
is it a fully closed system | The whole system is a fully closed system, there will be no oil mist at high temperature, and the water in the air will not be absorbed at low temperature. The system will not increase the pressure due to high temperature in operation, and the thermal conduction medium will be automatically supplemented at low temperature. | |||
refrigerant | R404A/R507C/R125/N40 All four refrigerants are available | |||
Connection size | There are six groups of inlet and outlet,ZG3/4 | |||
Cooling water at 20C° | 6000L/H | 9000L/H | 15000L/H | |
Condenser(W) | Shenshi tube type heat exchanger | |||
Power 380V50HZ | 38kW | 55kW | 82kW | |
Dimension cm | 200*145*205 | 200*145*205 | 200*145*205 | |
Weight | 900kg | 1200kg | 1950kg | |
Optional | 220V 60HZ three phase 460V 60H three phase | |||
Optional | Extend to -40~+135℃ | |||
Optional | The size external circulation pipe line is DN15 or DN20, do not throttle, which will increase the circulation pump load, | |||
pipe need to be insulated, and adopt rubber and plastic insulation pipe which can afford high temp. | ||||
Optional | When the temperature is lower than the normal temperature, the refrigeration system adopts the refrigeration PID to adjust the cooling capacity, and does not adopt the heating countermeasures, so as to achieve the purpose of energy saving |
Configuration Details
Working Principle
Temperature simulation for vehicle quality test: battery life test, fuel injector/motor test bench, airbag test, component test bench, etc. It can simulate the external environmental conditions in the climate chamber or replace the internal system, which can create the necessary actual temperature conditions for the test bench.
Test temperature of main test items of vehicle electronics:
IC test conditions for locomotives: -40℃~125℃, wind blowing, sun exposure, high vibration;
Instrument panel operation test test conditions: -40℃~85℃;
Motor controller test conditions: operating test temperature: 40 ℃ ~ 110 ℃;
Satellite positioning (GPS) Test conditions: high temperature operation test temperature: 85℃; low temperature operation test temperature: -40℃;
Compound vibration: -40℃~80℃;
Obviously the best solution is for the test house to have temperature simulation system equipment.
The model KRY 0℃~100℃ products can water-cooled chiller and air-cooled chiller.
RELATED PRODUCTS
Switch more- VIEW
KRY -20℃~100℃
Heating Power 15kW~38kW Cooling capacity 10kW~60kW
- VIEW
KRY -25℃~100℃
Heating Power 5.5kW~25kW Cooling capacity 2.8kW~38kW
- VIEW
KRY -40℃~100℃
Heating Power 5.5kW~38kW Cooling capacity 1.2kW~60kW