tag or keyword Search the whole station

Chillers

>What a Chillers?

Chiller, commonly known as the cooling circulator, is a cooling water equipment that can provide constant temperature, constant flow and constant pressure. The main function is to cool the water in the working host to keep it within a certain temperature.

In the refrigeration industry, water chillers can be divided into two types according to the heat removal method: air-cooled water chillers and water-cooled water chillers. In terms of temperature control, it is divided into low-temperature industrial water chiller and normal temperature water chiller. The temperature of normal temperature unit is generally controlled within the range of 0 ℃ to 35 ℃. The temperature control of low-temperature unit is generally around 0 ℃ to – 150 ℃.

>LNEYA Chiller’s Applications

For many years, industries have searched for ways to provide cooling for manufacturing processes. The basic air conditioner, introduced at the beginning of the twentieth century, could not provide sufficient cooling for large buildings, production processes, high-capacity machinery, and assembly operations.

Industrial:(Vehicle test , Semiconductor test,Manufacturing equipment……)

Plastic Manufacturing:

Metal Plating:

Phatmaceutical:(Reactor jacket,Rotary evaporator,Distillation system…..)

>How to Choose a Chiller?

√ Product Size

√ Cooling Capacity

√ Temperature Control Range

√ Energy Consumption

√ Installation Space and Environment

√ Energy Efficiency Ratio

√ Investment Budget

>Types of Chillers

We specialize in the production of refrigerated circulator with a temperature control range as low as -150°C, which can meet the refrigeration needs of different industries.

Temperature Range LX-25°C ~ -5°C LT-45°C ~ -10°C LT-60°C ~ -10°C LT-80°C ~ -30°CLT-110°C ~ -50°C
Cooling Capacityup to 30kWup to 12kWup to 6kWup to 6kWup to 5kW

Ultra Temperature Chillers (Water Cooled Chillers)

We specialize in the production of low-temperature chillers with a temperature control range as low as -150°C, which can meet the refrigeration needs of different industries.

Temperature Range LC -25℃~-5℃ LJ -45℃~-10℃ LN -60℃~-10℃ LD -80℃~-30℃ CDLJ -110℃~-50℃
Cooling Capacityup to 360kWup to 180kWup to 180kWup to 180kWup to 120kW

Recirculating Chillers/Water Chiller

The chiller can be widely used in various industries and laboratories, and supports customized design.

Temperature RangeFL +5°C ~ +35°C
Cooling Capacityup to 50kW

Gas Cooled Ultra Low Temp Chillers

Customized solutions for your business.

Temperature RangeSLJ -150°C ~ -110°C
Cooling Capacityup to 11kW

Vehicle Quality Testing Chillers (Water Cooled/ Air Cooled)

Temperature simulation for vehicle quality test: battery life test, fuel injector/motor test bench, airbag test, component test bench, etc.

Temperature Range KRY -25°C ~ +100°C KRY -40°C ~ +100°CKRY 0°C ~ +100°C KRY -20°C ~ +100°C
Cooling Capacityup to 38kWup to 60kWup to 60kWup to 60kW

Semiconductor Test Chillers (TES series)

Suitable for precise temperature control of electronic components. In the manufacture of semiconductor electronic components for harsh environments, the IC packaging assembly and engineering and production testing phases include electronic thermal testing and other environmental testing simulations.

Temperature range TES -45°C ~ +250°C TES-85°C ~+200°CTES -60°C ~+200°C
Cooling Capacityup to 25kWup to 25kWup to 60kW

Cooling and Heating System (Fluorinated Liquid)

Suitable for precise temperature control of electronic components. In the manufacture of semiconductor electronic components for harsh environments, the IC packaging assembly and engineering and production testing phases include electronic thermal testing and other environmental testing simulations.

Temperature rangeLTS-20°C ~ +80°CLTS-45°C ~ +80°CLTS -60°C ~ +80°CLTS -80°C ~ +80°C
Flow Control7 ~ 45 L/min7 ~ 45 L/min7 ~ 45 L/min7 ~ 45 L/min

> Why should you choose us for your custom chillers manufacturing?

We offer:

Experience you can count on—

We’ve been designing and building custom chillers for more than 20 years. From medical chillers to energy storage chillers and everything in between, we’ve built chillers for virtually every industry and every application.

Same day quotes—

Get a quote for your project today! We often provide custom quotes in as little as 30 minutes.

24/7 customer service—

We are always here for you. Whether you have a question or need a quote, there’s always somebody here to communicate with you 24/7.

Durable, reliable equipment—

Our products are built with premium-grade materials, and we offer competitive warranties on all custom chillers.

We specializes in custom chiller products. We have our liquid chiller system designs in everything from Semiconductor process equipment, FCEV Hydrogen Refeuling Stations and Bio-Pharmaceutical OEM process control systems. LNEYA can design any shape to fit around your equipment, pump selections to meet all your needs, air-cooled, water-cooled, multiple cooling loops. Special interface requirements, digital or analog, pump output heat transfer fluid flow and pressure control, temperature cycling and ramping all available.

Contact us today and learn more about our abilities in manufacturing custom chillers. Our staff welcomes any application challenges concerning your custom chillers.

How Chillers Work?

Though there are a wide variety of chillers, the majority of them use the same principle for removing heat. An essential part of the process is the coolant or refrigerant, which holds more heat than water and aids in maintaining an efficient cooling process. Heat is removed from the coolant and released into the air. The concept of a chiller is based on the principle that cooling involves the removal of heat from a process and releasing it into the air.

All chillers have a condenser, compressor, expansion valve, and evaporator that circulate a fluid or refrigerant. The process of a chiller is designed to transform the refrigerant from a liquid to a vapor and back to a liquid. In its vapor form, the refrigerant removes the heat from a process. When it is returned to its liquid form by the compressor and condenser, it circulates back through the system to capture the heat from a process or operation.

The chiller is mainly composed of refrigeration system, water system and control system. The refrigeration system is composed of one or two independent compressor refrigeration systems. Each compressor refrigeration system includes compressor, condenser, condensing fan, thermal expansion valve, plate heat exchanger and refrigerant pipeline.

Chillers Maintenance

Though the basic mechanism of a chiller is the same for all types, as with any type of industrial equipment, regular maintenance guarantees that it will perform according to its specifications.

A chiller unit is a cooling mechanism designed to produce fluids that can lower temperatures by removing heat from the fluid.

Although the maintenance status and product performance may vary greatly depending on the use environment, the general durability is considered to be about 6 years.

You may feel that the service life of the chiller is too short, and the legal service life is set to 15 years, but the service life and service life are not equal at first.

The statutory service life is the depreciation standard formulated by the Ministry of Finance, which does not mean that it can be used.

Therefore, the cooling performance may decline or stop working within 15 years.

Considering the durability of the chiller, it is necessary to select a new or used one.

Although large water chillers have high cooling capacity, they may not be installed in smaller rooms due to the space required.

If it is a small water chiller, it can be used wherever it is installed.

Those who consider introducing water chillers will have to choose one of the types of air cooling according to the heat dissipation method and structure.

According to the environment of the installation location, the best equipment will be determined.

If you are not sure about your decision, you can consult LNEYA.

Submit your requirements to us, we will contact you within 24 hours
*
*
submitting….
Submitted successfully!
Submission Failed! Please try again later.
E-mail error!
Phone error!
Leave a message
Leave a message
1
Leave a message