Microchannel Reactor Chillers – LNEYA Chillers https://www.lneyachillers.com -Air Cooled Chillers Manufacturer; Water-Cooled Chillers Manufacturer;Industrial Chillers; Recirculating Chillers Fri, 28 Apr 2023 01:16:40 +0000 zh-Hans hourly 1 https://wordpress.org/?v=6.6.2 https://www.lneyachillers.com/wp-content/uploads/2022/11/cropped-logo-150-32x32.png Microchannel Reactor Chillers – LNEYA Chillers https://www.lneyachillers.com 32 32 WTD -70℃~200℃ https://www.lneyachillers.com/wtd-70200-microchannelchiller.html https://www.lneyachillers.com/wtd-70200-microchannelchiller.html#respond Fri, 18 Nov 2022 03:22:11 +0000 https://www.lneyachillers.com/?p=892
WTD -70℃~200℃ For microchannel reactor
WTD -70℃~200℃ For microchannel reactor
WTD -70℃~200℃ For microchannel reactor

WTD -70℃~200℃ Cooling Heating System

Special for microchannel/tubular reactor
  • Heating Power38kW~50kW
  • Cooling capacity12kW~50kW
  • Circulation fulid50L~60L
  • Temperature accuracy±0.3℃
  • Temperature resolution0.1K
  • Weight2500KG~2600KG
  • Details

Parameters Detailed

Cooling heating and temperature control system (for microchannel/tubular reactor)

It is specially designed and developed for the characteristics of small liquid holding capacity, strong heat exchange capacity, and large pressure drop in the circulation system of the microchannel reactor.

  1. Optimize temperature sampling and response speed, specially design control algorithm, can respond quickly to stable temperature control.
  2. Enhance the design of the circulating pump capacity to meet the high pressure drop requirements of the reactor.
  3. Continuous high temperature cooling technology to meet the requirement of stable operation when the temperature control is required for high temperature exothermic reaction.

Model WTD-2A38W-2TE2WTD-4A38W-2TE2WTD-7A50WE2
Temperature range -25~200°C  -45~200°C-70~200°C
System circulating fluid30L+30L      30L+30L    50L
Expansion tank volume120L120L100L
Heating power38KW            38kw50kw
Circulating pump max250L/min 3bar        250L/min 3bar   250L/min 3bar   
Cooling water volume25 cubic/h  1BAR~4bar  max  DN65 PN1028 cubic/h  1BAR~4bar  max  DN65 PN1028 cubic/h 1BAR~4bar  max DN65 PN10
Refrigerant200L200L150L
Size3000*2000*22003000*2000*22003000*2000*2200
Weight2500KG2600KG2600KG
Power supply380V 50HZ  110KW  MAX  380V 50HZ 125KW MAX380V 50HZ 120KW MAX
Temperature control accuracy±0.5℃
Temperature resolution0.1K
Operation panelSiemens 7-inch color explosion-proof touch screen
Data curveData curve record
Data output U disk excel format
Temperature control accuracyGuanya Control System Siemens PLC
HeaterLeehom heating power 3W/cm2
Heating actuatorVoltage regulating actuator 4~20mA control
Oil interface sizeDN50 PN16            
Cooling water heat exchangerDouble tube heat exchanger
CompressorEmerson Copeland Scroll Flexible Compressor
Temperature SensorPT100 Liquid temperature at inlet and outlet of each group
RefrigerantSynthetic heat transfer oil
Pipe materialSUS304
Low voltage electricalSchneider/Siemens
Explosion-proof formPositive pressure explosion-proof explosion-proof product installation license number: PCEC-2017-B025

Working Principle

The model WTD -70℃~200℃ products can air-cooled chiller.

RELATED PRODUCTS

Switch more

loading…

No more to see

]]>
https://www.lneyachillers.com/wtd-70200-microchannelchiller.html/feed 0
WTD -45℃~250℃ https://www.lneyachillers.com/wtd-45250-microchannelchiller.html https://www.lneyachillers.com/wtd-45250-microchannelchiller.html#respond Fri, 18 Nov 2022 03:15:30 +0000 https://www.lneyachillers.com/?p=890
WTD -45℃~250℃
WTD -45℃~250℃
WTD -45℃~250℃

WTD -45℃~250℃ Cooling Heating System

Special for microchannel/tubular reactor
  • Heating Power5.5kW
  • Cooling capacity1.5kW~5.5kW
  • Circulation fulid9.5L
  • Temperature accuracy±0.3℃
  • Temperature resolution0.1K
  • RefrigerantR404A
  • Details

Parameters Detailed

Cooling heating and temperature control system (for microchannel/tubular reactor)

It is specially designed and developed for the characteristics of small liquid holding capacity, strong heat exchange capacity, and large pressure drop in the circulation system of the microchannel reactor.

  1. Optimize temperature sampling and response speed, specially design control algorithm, can respond quickly to stable temperature control.
  2. Enhance the design of the circulating pump capacity to meet the high pressure drop requirements of the reactor.
  3. Continuous high temperature cooling technology to meet the requirement of stable operation when the temperature control is required for high temperature exothermic reaction.

Model WTD-255-2T  Dual temperature zoneWTD-455-2T  Dual temperature zone
Temperature range -25°C~200°C  -45°C~250°C  
Temperature control accuracy±0.3℃±0.3℃
Temperature resolution0.1K0.1K
Operation panel7 inch color touch screen7 inch color touch screen
Data curveData curve recordData curve record
Data output U disk excel formatU disk excel format
Control modeFuzzy PID adaptive controllerFuzzy PID adaptive controller
Communication9L      9L      
Interface
System circulating fluid
12L17L built-in automatic constant temperature cooling system
Expansion tank volume5.5KW            5.5KW            
Heating power/5.5kw
Circulating pump max25L/min 3bar     Two way25L/min 3bar       Two way
Connection sizeR3/4            Two wayR3/4            Two way
Temperature SensorPT100    PT100  
Display 2 sets of inlet and outlet liquid temperatureDisplay 2 sets of inlet and outlet liquid temperature
CompressorEmerson CopelandEmerson Copeland
EvaporatorGaoli Plate Heat ExchangerGaoli Plate Heat Exchanger
Cooling methodAir cooling + water coolingAir cooling + water cooling
Expansion valveDanfoss expansion valveDanfoss expansion valve
Filter drierDanfossDanfoss
RefrigerantSynthetic heat transfer oilSynthetic heat transfer oil
Refrigerant25L25L
RefrigerantR404AR404A
Pipe materialSUS304SUS304
Ultra-high temperature cooling technologyYesYes
Metal insulation hose1.8M*4 root  1.8M*4 root 
Contactor\Circuit BreakerSchneiderSchneider
Size cm70*100*175  Wind up70*100*175  Wind up
Weight325KG365KG
Power supply380V 50HZ  17KW  MAX  380V 50HZ  19KW  MAX  
Temperature control accuracy±0.3℃
Temperature resolution0.1K
Operation panel7 inch color touch screen
Data curveData curve record
Data output U disk excel format
Control mode
CommunicationRS485 Modbus RTU协议

Working Principle

The model WTD -45℃~250℃ products can air-cooled chiller.

RELATED PRODUCTS

Switch more

loading…

No more to see

]]>
https://www.lneyachillers.com/wtd-45250-microchannelchiller.html/feed 0
WTD -20℃~300℃ https://www.lneyachillers.com/wtd-20300-chiller.html https://www.lneyachillers.com/wtd-20300-chiller.html#respond Fri, 18 Nov 2022 03:09:00 +0000 https://www.lneyachillers.com/?p=885
WTD -20℃~300℃
WTD -20℃~300℃
WTD -20℃~300℃
WTD -20℃~300℃

WTD -20℃~300℃ cooling heating system

Special for microchannel/tubular reactor
  • Heating Power2.5kW~7.5kW
  • Cooling capacity2kW~7.5kW
  • Circulation fulid2.5L~5.5L
  • Temperature accuracy±0.3℃
  • Temperature resolution0.1K
  • RefrigerantR404A
  • Details

Parameters Detailed

Cooling heating and temperature control system (for microchannel/tubular reactor)

It is specially designed and developed for the characteristics of small liquid holding capacity, strong heat exchange capacity, and large pressure drop in the circulation system of the microchannel reactor.

  1. Optimize temperature sampling and response speed, specially design control algorithm, can respond quickly to stable temperature control.
  2. Enhance the design of the circulating pump capacity to meet the high pressure drop requirements of the reactor.
  3. Continuous high temperature cooling technology to meet the requirement of stable operation when the temperature control is required for high temperature exothermic reaction.

Model WTD-120MWTD-255WTD-455WTD-755WTD-275V
Temperature range -5°C~120°C-25°C~200°C-45°C~250°C-70°C~200°C-20°C~300°C
Interface
System circulating fluid
2.5L4.5L4.5L5.5L5.5L
Expansion tank volume10L10L15L15L
Heating power2KW5.5KW5.5KW5.5KW7.5KW
Circulating pump max7L/min 2.5bar25L/min 3bar25L/min  3ar25L/min  3ar25L/min  3ar
Connection sizeR1/2R3/4R3/4R3/4R3/4
Temperature SensorPT100PT100PT100PT100PT100
CompressorSkopEmerson CopelandEmerson CopelandTaikangEmerson Copeland
EvaporatorPlate heat exchangerPlate heat exchangerPlate heat exchangerPlate heat exchangerPlate heat exchanger
Cooling methodAir cooling Air cooling + water coolingAir cooling + water coolingAir cooling + water coolingAir cooling + water cooling
Expansion valveDanfossDanfossDanfossDanfoss thermal expansion valve + Emerson electronic expansion valveDanfoss thermal expansion valve
Filter drierDanfossDanfossDanfossDanfossDanfoss
RefrigerantSynthetic heat transfer oilSynthetic heat transfer oilSynthetic heat transfer oilSynthetic heat transfer oilSynthetic heat transfer oil
Refrigerant5L20L20L20L 20L 
RefrigerantR404AR404AR404AR404A R23R404A  
Pipe materialSUS304SUS304SUS304SUS304SUS304
Ultra-high temperature cooling technologyYesYesYesYesYes
Metal insulation hose1m*2 root1.8M*2 root1.8M*2 root1.8M*2 root1.8M*2 root
Contactor\Circuit BreakerSchneiderSchneiderSchneiderSchneiderSchneider
Size350*600*850550*680*1450550*680*1450550*1000*1750550*1000*1750
Weight195KG205KG325KG205KG
Temperature control accuracy±0.3℃
Temperature resolution0.1K
Operation panel7 inch color touch screen
Data curveData curve record
Data output U disk excel format
Control mode
CommunicationRS485 Modbus RTU协议

Working Principle

The model WTD -20℃~300℃ products can air-cooled chiller.

RELATED PRODUCTS

Switch more

loading…

No more to see

]]>
https://www.lneyachillers.com/wtd-20300-chiller.html/feed 0