Heating Circulators – LNEYA Chillers https://www.lneyachillers.com -Air Cooled Chillers Manufacturer; Water-Cooled Chillers Manufacturer;Industrial Chillers; Recirculating Chillers Thu, 27 Apr 2023 09:06:58 +0000 zh-Hans hourly 1 https://wordpress.org/?v=6.6.2 https://www.lneyachillers.com/wp-content/uploads/2022/11/cropped-logo-150-32x32.png Heating Circulators – LNEYA Chillers https://www.lneyachillers.com 32 32 UC +50℃~300℃ https://www.lneyachillers.com/uc-50-300.html https://www.lneyachillers.com/uc-50-300.html#respond Thu, 27 Apr 2023 07:51:05 +0000 https://www.lneyachillers.com/?p=2531
UC +50℃~300℃

UC +50℃~300℃ heating circulator

Can temperature control reaction material
  • Heating Power3.5kW~130kW
  • Cooling power1kW~130kW
  • Power range5kW~136kW
  • Temperture accuracy±0.5℃
  • Weight95kG~1400kG
  • Details

Parameters Detailed

  • Heating Circulator UC series with function from high temperature to cooling process, from 300℃~50℃.
  • Equipped with heating cooling container, with large heat transfer area, fast heat-up and cool-down, small heat transfer oil demand.
  • Can heat-up and cool-down continuously.
  • The whole cycle is full closed,there is no oil mist at high temperature, heat transfer oil can not be oxidized and browning.
  • With function of internal PT100 for correcting internal circulation.
  • The whole system is closed with expansion tank, the expansion tank and liquid circulation are thermal insulation, do not participate in liquid circulation, regardless of high or low temperature, the medium in expansion tank is limited to 60℃.

Configuration Details

Model UC-3530 UC-5530 UC-7530 UC-A1030 UC-A1530 UC-A2530 UC-A3830 UC-A6030 UC-A9530 UC-A13030
Temperature range 50℃~300℃
Controller PID adaptive controller
Temp. control optional Heat-conducting medium outlet temp. control
 Communication protocol MODBUS RTU protocol  RS 485 interface
Temperature feedback Heat-conducting medium temperature feedback PT100
Temp. accuracy ±0.5℃
Heating power 3.5kW 5.5kW 7.5kW 10kW 15kW 25kW 38kW 60kW 95kW 130kW
Cooling capacity 300℃ 3.5kW 5.5kW 7.5kW 10kW 15kW 25kW 38kW 60kW 95kW 130kW
  200℃ 3.5kW 5..5kW 7.5kW 10kW 13kW 25kW 38kW 60kW 95kW 130kW
  100℃ 2.8kW 4kW 5kW 7kW 12kW 20kW 30kW 48kW 76kW 100kW
  65℃ 1kW 1.8kW 2.2kW 3kW 5kW 8.5kW 12kW 19kW 30kW 40kW
Circulation pump Max35L/min 1.2BAR Max35L/min 1.2BAR Max50L/min 1.2BAR Max50L/min 1.2BAR Max110L/min 1.5BAR Max150L/min 1.5BAR Max200L/min 1.5BAR Max250L/min 2.5BAR Max400L/min 2.5BAR Max400L/min 2.5BAR
Heater Flanged pipe electric heater
Independent temperature limiter Lneya
Cooler Plate heat exchanger/Tube heat exchanger
Operation panel Display set temperature and measured temperature,key operation input temperature
Sefety protection Self-diagnostics;High pressure switch,overload relay、variety of security features such as thermal protection devices.
Closed circulation system The entire system is a fully enclosed system,no oil mist at high temperatures、low temperature does not absorb moisture in the air
System The system does not increase the pressure due to high temperature during operation,low temperature automatically replenishes the heat transfer medium.
Connection size ZG3/4 ZG3/4 ZG1 ZG1 ZG1 DN32 PN10 DN40 PN10 DN40 PN10 DN50 PN10 DN50 PN10
Dimensions cm 40*70*130 40*70*130 45*70*160 45*70*160 70*100*175 70*100*175 80*100*185 150*100*185 200*145*205 200*145*205
Weight kg 95 110 120 160 195 265 395 615 1220 1400
Power 5KW 7KW 9KW 12kw 17kw 28kw 41kw 65kw 101kw 136kw
Case material Cold rolled sheet spray
Optional Optional 7-inch color touch screen,recording temperature curve,data export using excel format
Optional SUS304 shell
Optional Optional external touch screen controller,communication line distance 10m
Optional Optional explosion-proof touch screen control system(ExdeIIBT4),communication line distance 10m
Optional power 220V 60HZ three phase,440V~480V 60HZ three phase

RELATED PRODUCTS

Switch more

loading…

No more to see

]]>
https://www.lneyachillers.com/uc-50-300.html/feed 0
UC +50℃~170℃ https://www.lneyachillers.com/uc-50200-heatingsystem.html https://www.lneyachillers.com/uc-50200-heatingsystem.html#respond Thu, 17 Nov 2022 08:14:46 +0000 https://www.lneyachillers.com/?p=797
UC +50℃~170℃
UC +50℃~170℃
UC +50℃~170℃

UC +50℃~170℃ heating circulator

Can temperature control reaction material
  • Heating Power3kW~38kW
  • Cooling power0.6kW~38kW
  • Power range2.2kW~39.5kW
  • Temperture accuracy±0.5℃
  • Weight30kG~380kG
  • Details

Parameters Detailed

  • Heating Circulator UC series with function from high temperature to cooling process, from 300℃~50℃.
  • Equipped with heating cooling container, with large heat transfer area, fast heat-up and cool-down, small heat transfer oil demand.
  • Can heat-up and cool-down continuously.
  • The whole cycle is full closed,there is no oil mist at high temperature, heat transfer oil can not be oxidized and browning.
  • With function of internal PT100 for correcting internal circulation.
  • The whole system is closed with expansion tank, the expansion tank and liquid circulation are thermal insulation, do not participate in liquid circulation, regardless of high or low temperature, the medium in expansion tank is limited to 60℃.

Model LY-5020 LY-A020 UC-5020 UC-A1020 UC-A1520
Temperature range 50℃~200℃
Controller PID adaptive controller
Temp. control optional Heat-conducting medium outlet temp. control
 Communication protocol  MODBUS RTU protocol  RS 485 interface
Temperature feedback Heat-conducting medium temperature feedback PT100
Temp. accuracy ±0.5℃
Heating power 5.5kw 10kw 5.5kw 10kw 15kw
Cooling capacity 200℃       5.5kw 10kw 15kw
100℃       4kw 8KW 12kw
65℃       1.8kw 3.4KW 5kw
Circulation pump   Max35L/min2BAR Max50L/min2BAR Max35L/min
2BAR
Max50L/min
2BAR
Max50L/min
2BAR
Heater Flanged pipe electric heater
Independent temperature limiter Lneya
Cooler Plate heat exchanger/Tube heat exchanger
Operation panel Display set temperature and measured temperature,key operation input temperature
Sefety protection Self-diagnostics;high pressure switch,overload relay、variety of security features such as thermal protection devices
Closed circulation system The entire system is a fully enclosed system,no oil mist at high temperatures、low temperature does not absorb moisture in the air,the system does not increase the pressure due to high temperature during operation,the low temperature automatically replenishes the heat transfer medium
Connection size   ZG3/4 ZG3/4 ZG3/4 ZG3/4 ZG1
Dimensions cm   45*65*120 45*65*120 45*65*120 55*68*145 70*100*175
Weight   70kg 80kg 78kg 128kg 170kg
Power   AC 380V 50HZ AC 380V 50HZ AC 380V 50HZ AC 380V 50HZ AC 380V 50HZ
  5.9kW (max) 10.8kW (max) 5.9kW (max) 10.8kW (max) 15.7kW (max)
Case material Cold rolled sheet spray
Optional Optional 7-inch color touch screen,recording temperature curve,data export using excel format
Optional SUS304 shell
Optional power  220V 60HZ three phase,440V~460V 60HZ three phase

Configuration Details